+91-11-46089500-01  sales@kabuprojects.com

METAL PROCESSING SERIES

ATMOS SMS series units are designed, manufactured and tested at our state of the art factory in New Delhi, India to ensure optimal temperature for the crane electronics and cooling comfort for the cabin operator is maintained.

         The steel melting shop is one of the most integral parts of the steel making process where the electric arc furnace temperature can rise upto 1800 Deg. Celsius. High ambient temperatures, severe dust levels and heavy vibrations are experienced on all equipment operating on an EOT/Automated processing crane. These are the core focus areas applied to the ATMOS SMS series units. In order to maintain minimal or no downtime during steel production, it is imperative to reduce any equipment failure and eliminate any expensive maintenance procedures.

         Each unit is tailor made and our In-house testing laboratory capable of recreating similar conditions of an Industrial Plant ensure that only those units are quality passed which can withstand the severe environment of a Steel Melting Shop or a Smelter.

  Previous    Go to Coke oven  

ATMOS PF1


  • MODEL: ATMOS PF1
  • DESIGN: Stand-alone unit (Compact).
  • AIR INLET/OUTLET: Front (flush) side

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Not Applicable.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Provision of fresh air inlet through bypass channel to optimize crane cabin driver’s production performance.

KW

2.5 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

TECHNICAL DATA
  • Model: ATMOS PF1
  • Cooling capacity: 2.5 KW
  • At ambient temperature:55°C
  • Applicable up to min/max. ambient temperature:25/65°C
  • Circulated air flow blowing each evaporator: 650 m3/h
  • Compressor typeScroll
  • Evaporator TypeFront (flush) side
  • Refrigerant TypeR134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

PHYSICAL MEASUREMENTS

Dimensions – Main Unit.

  • Length 504 mm
  • Width 562 mm
  • Height 1072 mm
  • Weight Approx. 120 Kg

ATMOS PF2


  • MODEL: ATMOS PF2
  • DESIGN: Stand-alone unit (Compact).
  • AIR INLET/OUTLET: Front (flush) side

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Not Applicable.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Provision of fresh air inlet through bypass channel to optimize crane cabin driver’s production performance.

KW

4 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

TECHNICAL DATA
  • Model: ATMOS PF2
  • Cooling capacity: 4 KW
  • At ambient temperature:55°C
  • Applicable up to min/max. ambient temperature:25/65°C
  • Circulated air flow blowing each evaporator: 900 m3/h
  • Compressor typeScroll
  • Evaporator TypeFront (flush) side
  • Refrigerant TypeR134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

PHYSICAL MEASUREMENTS

Dimensions – Main Unit.

  • Length 600 mm
  • Width 650 mm
  • Height 1535 mm
  • Weight Approx. 135 Kg

ATMOS PF3


  • MODEL: ATMOS PF3
  • DESIGN: Stand-alone unit (Compact).
  • AIR INLET/OUTLET: Front (flush) side

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Not Applicable.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Provision of fresh air inlet through bypass channel to optimize crane cabin driver’s production performance.

KW

6 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

TECHNICAL DATA
  • Model: ATMOS PF3
  • Cooling capacity: 6 KW
  • At ambient temperature:55°C
  • Applicable up to min/max. ambient temperature:25/65°C
  • Circulated air flow blowing each evaporator: 1300 m3/h
  • Compressor typeScroll
  • Evaporator TypeFront (flush) side
  • Refrigerant TypeR134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

PHYSICAL MEASUREMENTS

Dimensions – Main Unit.

  • Length 600 mm
  • Width 700 mm
  • Height 1595 mm
  • Weight Approx. 210 Kg

ATMOS SABB-40


  • MODEL: ATMOS SABB-40
  • DESIGN: Stand-alone unit (Compact).
  • AIR INLET/OUTLET: Bottom/Bottom

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Not Applicable.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Provision of fresh air inlet through bypass channel to optimize crane cabin driver’s production performance.

KW

4 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

TECHNICAL DATA
  • Model: ATMOS SABB-40 NM, Split-Type`Z
  • Cooling capacity: 4 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing each evaporator: 1000 m3/h
  • Compressor type: Hermetic Scroll
  • Air Inlet and Outlet: Bottom
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

PHYSICAL MEASUREMENTS

Physical measurements like length, width and height.

  • Length 1065 mm
  • Width 630 mm
  • Height 1195 mm
  • Weight Approx. 140 Kg

ATMOS SAST-60


  • MODEL: ATMOS SAST-60
  • DESIGN: Stand-alone unit (Compact).
  • AIR INLET/OUTLET: SIDE/TOP

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Not Applicable.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Provision of fresh air inlet through bypass channel to optimize crane cabin driver’s production performance.

KW

6 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

TECHNICAL DATA
  • Model: ATMOS SAST-60
  • Cooling capacity: 6 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing through evaporator: 1100 m3/h
  • Compressor type: Hermetic Scroll
  • Evaporator type: Side/Top
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

PHYSICAL MEASUREMENTS

Physical measurements like length, width and height.

  • Length 1050 mm
  • Width 600 mm
  • Height 1080 mm
  • Weight Approx. 205 Kg

ATMOS SAST-80


  • MODEL: ATMOS SAST-80
  • DESIGN: Stand-alone unit (Compact).
  • AIR INLET/OUTLET: SIDE/TOP

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Not Applicable.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Provision of fresh air inlet through bypass channel to optimize crane cabin driver’s production performance.

KW

8 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

TECHNICAL DATA
  • Model: ATMOS SAST-80
  • Cooling capacity: 8 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing through evaporator: 1800 m3/h
  • Compressor type: Hermetic Scroll
  • Evaporator type: Side/Top
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

PHYSICAL MEASUREMENTS

Physical measurements like length, width and height.

  • Length 1360 mm
  • Width 620 mm
  • Height 1615 mm
  • Weight Approx. 290 Kg

ATMOS SATT-60


  • MODEL: ATMOS SATT-60
  • DESIGN: Stand-alone unit (Compact).
  • AIR INLET/OUTLET: TOP/TOP

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Not Applicable.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Provision of fresh air inlet through bypass channel to optimize crane cabin driver’s production performance.

KW

6 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

TECHNICAL DATA
  • Model: ATMOS SATT-60
  • Cooling capacity: 6 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing through evaporator: 900 m3/h
  • Compressor type: Hermetic Scroll
  • Evaporator type: Top/Top
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

PHYSICAL MEASUREMENTS

Physical measurements like length, width and height.

  • Length 920 mm
  • Width 620 mm
  • Height 1335 mm
  • Weight Approx. 180 Kg

ATMOS SATT-80


  • MODEL: ATMOS SATT-80
  • DESIGN: Stand-alone unit (Compact).
  • AIR INLET/OUTLET: TOP/TOP

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Not Applicable.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Provision of fresh air inlet through bypass channel to optimize crane cabin driver’s production performance.

KW

8 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

TECHNICAL DATA
  • Model: ATMOS SATT-80
  • Cooling capacity: 8 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing through evaporator: 1700 m3/h
  • Compressor type: Hermetic Scroll
  • Evaporator type: Top/Top
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

PHYSICAL MEASUREMENTS

Physical measurements like length, width and height.

  • Length 1320 mm
  • Width 600 mm
  • Height 1600 mm
  • Weight Approx. 354 Kg

ATMOS SATT-120


  • MODEL: ATMOS SATT-120
  • DESIGN: Stand-alone unit (Compact).
  • AIR INLET/OUTLET: TOP/TOP

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Not Applicable.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Provision of fresh air inlet through bypass channel to optimize crane cabin driver’s production performance.

KW

12 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

TECHNICAL DATA
  • Model: ATMOS SATT-120
  • Cooling capacity: 12 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing through evaporator: 2200 m3/h
  • Compressor type: Hermetic Scroll
  • Evaporator type: Top/Top
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

PHYSICAL MEASUREMENTS

Physical measurements like length, width and height.

  • Length 1500 mm
  • Width 830 mm
  • Height 2002 mm
  • Weight Approx. 430 Kg

ATMOS STFM-40


  • MODEL: ATMOS STFM-40
  • DESIGN: Split Type (Floor Mounted).
  • AIR INLET/OUTLET: Front/Front

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Special type flexible rubber insulated interconnecting kit to withstand heavy vibration.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Not Applicable.

KW

4 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 524 mm
  • Width 313 mm
  • Height 1025 mm
  • Weight Approx. 70 Kg
TECHNICAL DATA
  • Model: ATMOS STFM-40
  • Cooling capacity: 4 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing each evaporator: 800 m3/h
  • Compressor type: Scroll
  • Evaporator type: Floor Mounted (Indoor)
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

CONDENSER PHYSICAL MEASUREMENTS

Condenser physical measurements like length, width, height and weight.

  • Length 1050 mm
  • Width 610 mm
  • Height 915 mm
  • Weight Approx. 130 Kg

ATMOS STFM-60


  • MODEL: ATMOS STFM-60
  • DESIGN: Split Type (Floor Mounted).
  • AIR INLET/OUTLET: Front/Front

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Special type flexible rubber insulated interconnecting kit to withstand heavy vibration.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Not Applicable.

KW

6 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 624 mm
  • Width 333 mm
  • Height 1125 mm
  • Weight Approx. 80 Kg
TECHNICAL DATA
  • Model: ATMOS STFM-60
  • Cooling capacity: 6 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing each evaporator: 1200 m3/h
  • Compressor type: Scroll
  • Evaporator type: Floor Mounted (Indoor)
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

CONDENSER PHYSICAL MEASUREMENTS

Condenser physical measurements like length, width, height and weight.

  • Length 1150 mm
  • Width 600 mm
  • Height 915 mm
  • Weight Approx. 220 Kg

ATMOS STFM-80


  • MODEL: ATMOS STFM-80
  • DESIGN: Split Type (Floor Mounted).
  • AIR INLET/OUTLET: Front/Front

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Special type flexible rubber insulated interconnecting kit to withstand heavy vibration.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Not Applicable.

KW

8 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 620 mm
  • Width 382 mm
  • Height 1255 mm
  • Weight Approx. 130 Kg
TECHNICAL DATA
  • Model: ATMOS STFM-80
  • Cooling capacity: 8 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing each evaporator: 1750 m3/h
  • Compressor type: Scroll
  • Evaporator type: Floor Mounted (Indoor)
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

CONDENSER PHYSICAL MEASUREMENTS

Condenser physical measurements like length, width, height and weight.

  • Length 1250 mm
  • Width 660 mm
  • Height 969 mm
  • Weight Approx. 250 Kg

ATMOS STFM-120


  • MODEL: ATMOS STFM-120
  • DESIGN: Split Type (Floor Mounted).
  • AIR INLET/OUTLET: Front/Front

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Special type flexible rubber insulated interconnecting kit to withstand heavy vibration.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Not Applicable.

KW

12 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 759 mm
  • Width 414 mm
  • Height 1678 mm
  • Weight Approx. 150 Kg
TECHNICAL DATA
  • Model: ATMOS STFM-120
  • Cooling capacity: 12 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing each evaporator: 2400 m3/h
  • Compressor type: Scroll
  • Evaporator type: Floor Mounted (Indoor)
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

CONDENSER PHYSICAL MEASUREMENTS

Condenser physical measurements like length, width, height and weight.

  • Length 1500 mm
  • Width 800 mm
  • Height 1201 mm
  • Weight Approx. 290 Kg

ATMOS STFM-180


  • MODEL: ATMOS STFM-180
  • DESIGN: Split Type (Floor Mounted).
  • AIR INLET/OUTLET: Front/Front

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Special type flexible rubber insulated interconnecting kit to withstand heavy vibration.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Not Applicable.

KW

18 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 620 mm
  • Width 380 mm
  • Height 1245 mm
  • Weight Approx. 236 Kg
TECHNICAL DATA
  • Model: ATMOS STFM-180
  • Cooling capacity: 18 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing each evaporator: 2 * 1950 m3/h
  • Compressor type: Scroll
  • Evaporator type: Floor Mounted (Indoor)
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

CONDENSER PHYSICAL MEASUREMENTS

Condenser physical measurements like length, width, height and weight.

  • Length 2390 mm
  • Width 990 mm
  • Height 1345 mm
  • Weight Approx. 850 Kg

ATMOS STFM-240


  • MODEL: ATMOS STFM-240
  • DESIGN: Split Type (Floor Mounted).
  • AIR INLET/OUTLET: Front/Front

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Special type flexible rubber insulated interconnecting kit to withstand heavy vibration.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Not Applicable.

KW

24 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 1510 mm
  • Width 780 mm
  • Height 1215 mm
  • Weight Approx. 300 Kg
TECHNICAL DATA
  • Model: ATMOS STFM-240
  • Cooling capacity: 24 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing each evaporator: 2 * 2400 m3/h
  • Compressor type: Scroll
  • Evaporator type: Floor Mounted (Indoor)
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

CONDENSER PHYSICAL MEASUREMENTS

Condenser physical measurements like length, width, height and weight.

  • Length 1700 mm
  • Width 900 mm
  • Height 1655 mm
  • Weight Approx. 850 Kg

ATMOS STWM-40


  • MODEL: ATMOS STWM-40
  • DESIGN: Wall mounted evaporator unit with outside mounted condenser unit.
  • AIR INLET/OUTLET: Front (flush) side

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Special type flexible rubber insulated interconnecting kit to withstand heavy vibration.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Not Applicable.

KW

4 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 695 mm
  • Width 343 mm
  • Height 680 mm
  • Weight Approx. 58 Kg
TECHNICAL DATA
  • Model: ATMOS STWM-40
  • Cooling capacity: 4 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing each evaporator: 800 m3/h
  • Compressor type: Scroll
  • Evaporator type: Wall Mounted (Indoor)
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

CONDENSER PHYSICAL MEASUREMENTS

Condenser physical measurements like length, width, height and weight.

  • Length 1050 mm
  • Width 610 mm
  • Height 809 mm
  • Weight Approx. 130 Kg

ATMOS STWM-60


  • MODEL: ATMOS STWM-60
  • DESIGN: Wall mounted evaporator unit with outside mounted condenser unit.
  • AIR INLET/OUTLET: Front (flush) side

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Special type flexible rubber insulated interconnecting kit to withstand heavy vibration.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Not Applicable.

KW

6 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 824 mm
  • Width 313 mm
  • Height 852 mm
  • Weight Approx. 65 Kg
TECHNICAL DATA
  • Model: ATMOS STWM-60
  • Cooling capacity: 6 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing each evaporator: 1500 m3/h
  • Compressor type: Scroll
  • Evaporator type: Wall Mounted (Indoor)
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

CONDENSER PHYSICAL MEASUREMENTS

Condenser physical measurements like length, width, height and weight.

  • Length 1150 mm
  • Width 600 mm
  • Height 915 mm
  • Weight Approx. 220 Kg

ATMOS STWM-80


  • MODEL: ATMOS STWM-80
  • DESIGN: Wall mounted evaporator unit with outside mounted condenser unit.
  • AIR INLET/OUTLET: Front (flush) side

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Special type flexible rubber insulated interconnecting kit to withstand heavy vibration.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Not Applicable.

KW

8 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 695 mm
  • Width 343 mm
  • Height 680 mm
  • Weight Approx. 116 Kg
TECHNICAL DATA
  • Model: ATMOS STWM-80
  • Cooling capacity: 8 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing each evaporator: 2 * 800 m3/h
  • Compressor type: Scroll
  • Evaporator type: Wall Mounted (Indoor)
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

CONDENSER PHYSICAL MEASUREMENTS

Condenser physical measurements like length, width, height and weight.

  • Length 1250 mm
  • Width 660 mm
  • Height 969 mm
  • Weight Approx. 250 Kg

ATMOS STWM-120


  • MODEL: ATMOS STWM-120
  • DESIGN: Wall mounted evaporator unit with outside mounted condenser unit.
  • AIR INLET/OUTLET: Front (flush) side

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Special type flexible rubber insulated interconnecting kit to withstand heavy vibration.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Not Applicable.

KW

12 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 824 mm
  • Width 313 mm
  • Height 852 mm
  • Weight Approx. 130 Kg
TECHNICAL DATA
  • Model: ATMOS STWM-120
  • Cooling capacity: 12 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing each evaporator: 2 * 1500 m3/h
  • Compressor type: Scroll
  • Evaporator type: Wall Mounted (Indoor)
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

CONDENSER PHYSICAL MEASUREMENTS

Condenser physical measurements like length, width, height and weight.

  • Length 1500 mm
  • Width 800 mm
  • Height 1201 mm
  • Weight Approx. 270 Kg

ATMOS STCM-40


  • MODEL: ATMOS STCM-40
  • DESIGN: Split Type (Celing Mounted).
  • AIR INLET/OUTLET: Back/Front

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement. Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special mining equipment such as Excavators, Dumpers, Dozers, Electric Rope Shovels, Draglines, Surface Miners & Spreaders.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Special type flexible rubber insulated interconnecting kit to withstand heavy vibration.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Not Applicable.

KW

4 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 682 mm
  • Width 570 mm
  • Height 285 mm
  • Weight Approx. 55 Kg
TECHNICAL DATA
  • Model: ATMOS STCM-40
  • Cooling capacity: 4 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing evaporator: 1200 m3/h
  • Compressor type: Hermetic Scroll
  • Evaporator type: Back and front
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

CONDENSER PHYSICAL MEASUREMENTS

Condenser physical measurements like length, width, height and weight.

  • Length 1050 mm
  • Width 610 mm
  • Height 809 mm
  • Weight Approx. 130 Kg

ATMOS STCM-60


  • MODEL: ATMOS STCM-60
  • DESIGN: Split Type (Celing Mounted).
  • AIR INLET/OUTLET: Back/Front

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement. Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special mining equipment such as Excavators, Dumpers, Dozers, Electric Rope Shovels, Draglines, Surface Miners & Spreaders.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Special type flexible rubber insulated interconnecting kit to withstand heavy vibration.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Not Applicable.

KW

6 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 833 mm
  • Width 620 mm
  • Height 309 mm
  • Weight Approx. 65 Kg
TECHNICAL DATA
  • Model: ATMOS STCM-60
  • Cooling capacity: 6 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing evaporator: 1300 m3/h
  • Compressor type: Hermetic Scroll
  • Evaporator type: Back and front
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

CONDENSER PHYSICAL MEASUREMENTS

Condenser physical measurements like length, width, height and weight.

  • Length 1150 mm
  • Width 600 mm
  • Height 915 mm
  • Weight Approx. 220 Kg

ATMOS STCM-80


  • MODEL: ATMOS STCM-80
  • DESIGN: Split Type (Celing Mounted).
  • AIR INLET/OUTLET: Back/Front

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Special type flexible rubber insulated interconnecting kit to withstand heavy vibration.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Not Applicable.

KW

8 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 682 mm
  • Width 570 mm
  • Height 285 mm
  • Weight Approx. 110 Kg
TECHNICAL DATA
  • Model: ATMOS STCM-80
  • Cooling capacity: 8 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing evaporator: 2 * 1200 m3/h
  • Compressor type: Hermetic Scroll
  • Evaporator type: Back and front
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

CONDENSER PHYSICAL MEASUREMENTS

Condenser physical measurements like length, width, height and weight.

  • Length 1250 mm
  • Width 660 mm
  • Height 969 mm
  • Weight Approx. 250 Kg

ATMOS STCM-120


  • MODEL: ATMOS STCM-120
  • DESIGN: Split Type (Celing Mounted).
  • AIR INLET/OUTLET: Back/Front

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as coking, steel melting, mines, transfer cars, pulp & paper, oil & gas refineries etc.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Special type flexible rubber insulated interconnecting kit to withstand heavy vibration.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Not Applicable.

KW

12 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 833 mm
  • Width 620 mm
  • Height 309 mm
  • Weight Approx. 130 Kg
TECHNICAL DATA
  • Model: ATMOS STCM-120
  • Cooling capacity: 12 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing evaporator: 2 * 1300 m3/h
  • Compressor type: Hermetic Scroll
  • Evaporator type: Back and front
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

CONDENSER PHYSICAL MEASUREMENTS

Condenser physical measurements like length, width, height and weight.

  • Length 1500 mm
  • Width 800 mm
  • Height 1201 mm
  • Weight Approx. 270 Kg

METAL PROCESSING - SAMPLE INSTALLATION

Sample INSTALLATION

STAND-ALONE UNITS (COMPACT)

SAMPLE INSTALLATION

SPLIT TYPE (CEILING MOUNTED)

SAMPLE INSTALLATION

SPLIT TYPE (FLOOR MOUNTED)

SAMPLE INSTALLATION

SPLIT TYPE (WALL MOUNTED)

SAMPLE INSTALLATION

STAND-ALONE UNITS (COMPACT)

SAMPLE INSTALLATION