+91-11-46089500-01  sales@kabuprojects.com

MINING DUTY SERIES

ATMOS Mining Duty series units are designed, manufactured and tested at our state of the art factory in New Delhi, India to ensure optimal temperature for the crane electronics and cooling comfort for the cabin operator is maintained.

         High ambient temperatures upto +60C in tropic ad desert temperatures zones due to high levels of sun radiation are a major factor to be considered to ensure non-stop functioning of Mining Equipment. The electronics installed in the cranes e-room or stand alone panels are very sensitive & inoperable at hot temperatures. Therefore, temperatures below +35C should be maintained inside the panels.

         The crane operator cabin also needs to be maintained at a comfortable room temperature of +23-25 Deg Celsius to ensure continuous work.

  Back to Port Cranes    Go to Explosion proof  

ATMOS STCM-40


  • MODEL: ATMOS STCM-40
  • DESIGN: Split Type (Celing Mounted).
  • AIR INLET/OUTLET: Back/Front

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement. Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special mining equipment such as Excavators, Dumpers, Dozers, Electric Rope Shovels, Draglines, Surface Miners & Spreaders.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Special type flexible rubber insulated interconnecting kit to withstand heavy vibration.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Not Applicable.

KW

4 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 682 mm
  • Width 570 mm
  • Height 285 mm
  • Weight Approx. 55 Kg
TECHNICAL DATA
  • Model: ATMOS STCM-40
  • Cooling capacity: 4 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing evaporator: 1200 m3/h
  • Compressor type: Hermetic Scroll
  • Evaporator type: Back and front
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

CONDENSER PHYSICAL MEASUREMENTS

Condenser physical measurements like length, width, height and weight.

  • Length 1050 mm
  • Width 610 mm
  • Height 809 mm
  • Weight Approx. 130 Kg

ATMOS STCM-60


  • MODEL: ATMOS STCM-60
  • DESIGN: Split Type (Celing Mounted).
  • AIR INLET/OUTLET: Back/Front

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement. Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special mining equipment such as Excavators, Dumpers, Dozers, Electric Rope Shovels, Draglines, Surface Miners & Spreaders.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Special type flexible rubber insulated interconnecting kit to withstand heavy vibration.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Not Applicable.

KW

6 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 833 mm
  • Width 620 mm
  • Height 309 mm
  • Weight Approx. 65 Kg
TECHNICAL DATA
  • Model: ATMOS STCM-60
  • Cooling capacity: 6 KW
  • At ambient temperature: 55°C
  • Applicable up to min/max. ambient temperature: 25/65°C
  • Circulated air flow blowing evaporator: 1300 m3/h
  • Compressor type: Hermetic Scroll
  • Evaporator type: Back and front
  • Refrigerant Type: R134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

CONDENSER PHYSICAL MEASUREMENTS

Condenser physical measurements like length, width, height and weight.

  • Length 1150 mm
  • Width 600 mm
  • Height 915 mm
  • Weight Approx. 220 Kg

ATMOS KR1


  • MODEL: ATMOS KR1
  • DESIGN: Special type unit (Compact).
  • AIR INLET/OUTLET: Side/Side

Designed for highly corrosive and dusty environments. Can withstand heavy vibrations and sporadic movement.Unit can operate in ambient temperatures up to 65°C. Indoor / Inside panel temperature can be set between 25-35°C (±2°C).Applications include many special areas such as Mining.

SERIES FUNCTIONS

Scroll over the circle to discover the functions it has to offer
Created with Raphaël 2.1.2

Interconnecting Pipeline

Not Applicable.

De-Dusting

Automatic de-dusting mechanism for uninterrupted cooling performance with minimum maintenance.

Condensate Evaporator

For safety and quality norms in production areas, condensate from the evaporator cannot be drained in the form of water during operation.

Trip Protection & Remote Monitering

Protection against phase lag, phase dislocation, motor loading & high / low pressure conditions optional output terminals are provide for future remote monitoring & control.

Fresh air inlet

Provision of fresh air inlet through bypass channel to optimize crane cabin driver’s production performance.

KW

5 KW at the performance of the unit at the ambient temperature of 55 C and inside temperature of 27C.

TECHNICAL DATA
  • Model: ATMOS KR1
  • Cooling capacity: 5 KW
  • At ambient temperature:55°C
  • Applicable up to min/max. ambient temperature:25/65°C
  • Circulated air flow blowing each evaporator: 1200 m3/h
  • Compressor typeScroll
  • Air Inlet and OutletSide Through Ducting
  • Refrigerant TypeR134a
  • Operating Conditions - Operating Voltage 380/415/460/480V and Frequency 50/60HZ.

EVAPORATOR PHYSICAL MEASUREMENTS

Evaporator physical measurements like length, width, height and weight.

  • Length 719 mm
  • Width 1087 mm
  • Height 526 mm
  • Weight Approx. 190 Kg

MINING DUTY - SAMPLE INSTALLATION

Sample INSTALLATION

STAND-ALONE UNITS (COMPACT)

SAMPLE INSTALLATION

SPLIT TYPE (CEILING MOUNTED)

SAMPLE INSTALLATION

SPLIT TYPE (FLOOR MOUNTED)

SAMPLE INSTALLATION

SPLIT TYPE (WALL MOUNTED)

SAMPLE INSTALLATION

STAND-ALONE UNITS (COMPACT)

SAMPLE INSTALLATION